Advanced Discrete Control of Three-Phase Grid-Connected Inverter
Jun 27, 2024 · Grid-connected inverters, recognized as one of the key elements in distributed generation systems, have been widely used in modern power systems. In recent literature,
Jun 27, 2024 · Grid-connected inverters, recognized as one of the key elements in distributed generation systems, have been widely used in modern power systems. In recent literature,
Dec 1, 2024 · This paper provides a proportional-integral (PI) controller and direct-quadrature (DQ) frame transformation-based optimum control method for a three-phase grid-connected
Mar 30, 2021 · This example implements the control for a three-phase PV inverter. Such a system can be typically found in small industrial
Dec 1, 2025 · Stability analysis for the grid-connected single-phase asymmetrical cascaded multilevel inverter with SRF-PI current control under weak grid conditions IEEE Trans. Power
Sep 22, 2022 · Presented in this paper is a method of bidirectional real and reactive power control of a three-phase grid-connected inverter under unbalanced grid situations.
Jun 1, 2025 · In this article, a novel control method of the grid-connected inverter (GCI) based on the off-policy integral reinforcement learning (IRL) method is presented to solve two-stage
Abstract - This paper presents a new multi-objective control strategy for inverter-interfaced distributed generation (IIDG) to ensure its safe and continuous operation under unbalanced
Oct 8, 2024 · In a three-phase symmetrical system, the stability of the positive sequence subsystem determines the stability of the grid-connected inverter [24]. Therefore, employing
Oct 8, 2024 · In a three-phase symmetrical system, the stability of the positive sequence subsystem determines the stability of the grid
Mar 30, 2021 · This example implements the control for a three-phase PV inverter. Such a system can be typically found in small industrial photovoltaic facilities, which are directly connected to
Jan 12, 2018 · Inverter-based distributed generation plays a vital role in the stability and reliability of new power systems. Under voltage sags, these systems must remain connected to the
Jun 8, 2025 · ABSTRACT The primary cascaded control loops and the phase-locked loop (PLL) can enable voltage source inverter operation in
Sep 22, 2022 · Presented in this paper is a method of bidirectional real and reactive power control of a three-phase grid-connected inverter under unbalanced grid situations.
Jun 8, 2025 · ABSTRACT The primary cascaded control loops and the phase-locked loop (PLL) can enable voltage source inverter operation in grid-forming and grid-following mode. This
PDF version includes complete article with source references. Suitable for printing and offline reading.
Presented in this paper is a method of bidirectional real and reactive power control of a three-phase grid-connected inverter under unbalanced grid situations. Unbalanced three-phase load and unbalanced grid impedance are illustrations of unbalanced grid issues that have been investigated.
The three-phase PV grid-connected inverter was designed based on the LQR method, where the tracking error was adjusted to zero through integration (Al-Abri et al., 2024). The disturbance rejection ability of the PV GCI was improved by designing the linear state inaccuracy feedback control policy (Zhou et al., 2021).
With the rapid development of distributed generation technologies, a large number of renewable energy sources, such as wind power, photovoltaic power and energy storage, are connected to the grids through power electronic devices, among which grid-connected inverters are the core components [1, 2].
However, reference improved and simplified this approach by using just one PLL, and power control can also be accomplished with a PI-controller. Using a proportional resonance (PR)-controller, power control of grid-connected three-phase inverters under unbalanced grid situations has been explored in [7, 8].